Test Files used for testing pydicom
-----------------------------------
I obtained images to test the pydicom code, and revised them as follow:
  * images were often downsized to keep the total file size quite small (typically <50K-ish). I wanted unittests for the code where I could run a number of tests quickly, and with files I could include in the source (and binary) distributions without bloating them too much
  * In some cases, the original files have been binary edited to replace anything that looks like a real patient name

I believe there is no restriction on using any of these files in this manner.

First, which transfer syntax the files are:
ExplVR_BigEnd.dcm       : Expl VR Big Endian
ExplVR_BigEndNoMeta.dcm : Expl VR Big Endian
MR_small_bigendian.dcm  : Expl VR Big Endian

color-pl.dcm            : Expl VR Little Endian
color-px.dcm            : Expl VR Little Endian
CT_small.dcm            : Expl VR Little Endian
ExplVR_LitEndNoMeta.dcm : Expl VR Little Endian
image_dfl.dcm           : Expl VR Little Endian
JPEG-LL.dcm             : Expl VR Little Endian
JPEG-lossy.dcm          : Expl VR Little Endian
JPEG2000.dcm            : Expl VR Little Endian
liver.dcm               : Expl VR Little Endian
MR_small.dcm            : Expl VR Little Endian
OBXXXX1A.dcm            : Expl VR Little Endian
reportsi.dcm            : Expl VR Little Endian
test-SR.dcm             : Expl VR Little Endian

MR_small_implicit.dcm   : Impl VR Little Endian
nested_priv_SQ.dcm      : Impl VR Little Endian
no_meta_group_length.dcm: Impl VR Little Endian
OT-PAL-8-face.dcm       : Impl VR Little Endian
priv_SQ.dcm             : Impl VR Little Endian
rtdose.dcm              : Impl VR Little Endian
rtplan.dcm              : Impl VR Little Endian
rtplan_truncated.dcm    : Impl VR Little Endian
rtstruct.dcm            : Impl VR Little Endian

CT_small.dcm
  * CT image, Explicit VR, LittleEndian
  * Downsized to 128x128 from 'CT1_UNC', ftp://medical.nema.org/MEDICAL/Dicom/DataSets/WG04/

MR_small.dcm
  * MR image, Explicit VR, LittleEndian
  * Downsized to 64x64 from 'MR1_UNC', ftp://medical.nema.org/MEDICAL/Dicom/DataSets/WG04/
  * Explicit VR big endian version created using DCMTK's dcmconv for PR #714

MR_small_implicit.dcm
  * The same dataset as MR_small, saved with Implicit VR using dcmodify

MR_small_bigendian.dcm
  * The same dataset as MR_small, saved as Big Endian using dcmodify

JPEG2000.dcm
  * JPEG 2000 small image
  * to test JPEG transfer syntax, eventually JPEG decompression
  * Edited 'NM1_J2KI' from ftp://medical.nema.org/MEDICAL/Dicom/DataSets/WG04

image_dfl.dcm
  * Compressed (using "deflate" zlib compression) after FileMeta
  * 'image_dfl' from http://www.dclunie.com/images/compressed/

ExplVR_BigEnd.dcm
  * Big Endian test image
  * Also is Samples Per Pixel of 3 (RGB)
  * Downsized to 60x80 from 'US-RGB-8-epicard' at http://www.barre.nom.fr/medical/samples/

JPEG-LL.dcm
  * NM1_JPLL from ftp://medical.nema.org/MEDICAL/Dicom/DataSets/WG04/
  * Transfer Syntax 1.2.840.10008.1.2.4.70:  JPEG Lossless Default Process 14 [Selection Value 1]

JPEG-lossy.dcm
  * NM1_JPLY from ftp://medical.nema.org/MEDICAL/Dicom/DataSets/WG04/
  * 1.2.840.10008.1.2.4.51 Default Transfer Syntax for Lossy JPEG 12-bit
  * GDCM prints when reading this file: "Unsupported JPEG data precision 12" and "Invalid SOS parameters for sequential JPEG", although it does appear to be read properly

liver.dcm
  * The DICOM SEG example was generated using the dcmqi library: https://github.com/qiicr/dcmqi
  * Provided by Andrey Fedorov (@fedorov)
  * Explicit VR big endian versions created using DCMTK's dcmconv and a script
    used to fix the pixel data for PR #714
  * Single frame versions created using a script for PR #714

Created by a commercial radiotherapy treatment planning system and modified:
rtplan.dcm       Implicit VR, Little Endian
rtdose.dcm       Implicit VR, Little Endian
  * Explicit VR big endian version created using DCMTK's dcmconv and the
    pixel data corrected using script for PR #714
  * Single frame version created using a script for PR #714
  * RLE encoded versions created using GDCM's gdcmconv for PR #708

chr*.dcm
  * Character set files for testing (0008,0005) Specific Character Set
  * from http://www.dclunie.com/images/charset/SCS*
  * downsized to 32x32 since pixel data is irrelevant for these (test pattern only)

test_SR.dcm
  * from ftp://ftp.dcmtk.org/pub/dicom/offis/software/dscope/dscope360/support/srdoc103.zip, file "test.dcm"
  * Structured Reporting example, many levels of nesting

priv_SQ.dcm
  * a file with an undefined length SQ item in a private tag.
  * minimal data elements kept from example files in issues 91, 97, 98

OBXXXX1A.dcm
  * a file with a Photometric Interpretation of PALETTE COLOR
  * used to check if to pixel_array is interpreted correctly for such a case
  * taken from https://github.com/pydicom/pydicom/issues/205#issuecomment-103329677
  * supposedly from a Philips machine
  * Explicit VR big endian version created using DCMTK's dcmconv and the
    pixel data corrected using script for PR #714
  * 2 frame version created using a script for PR #714
  * RLE encoded versions created using GDCM's gdcmconv for PR #708

OT-PAL-8-face.dcm
  * a file with a Photometric Interpretation of PALETTE COLOR
  * used to check if to pixel_array is interpreted correctly for such a case
  * taken from http://www.barre.nom.fr/medical/samples/

SC_rgb.dcm
  * 16 and 32 bit versions created using a script for PR #714
  * Explicit VR big endian version created using DCMTK's dcmconv and the
    pixel data corrected using script for PR #714
  * 2 frame versions created using a script for PR #714
  * RLE encoded versions created using GDCM's gdcmconv for PR #708

zipMR.gz
  * a gzipped version of MR_small.dcm
  * used for checking that deferred read reopens as zip again (issue 103)

== DICOMDIR tests ==

dicomdirtests files were from http://www.pcir.org, freely available image sets.
They were downsized to 16x16 images to keep them very small so they
could be added to the source distribution without bloating it. For the
same reason, many were removed, leaving only samples of the studies,
series, and images.

For the subdirectories ending in "N" (e.g. CT2N, CT5N), the name indicates
the number of images inside the folder, i.e. CT2N has two images,
CT5N has five. This was a memory-aid for use in unit tests.

Below is the hierarchy of Patient, Study, Series, Images that comes from a
straight read of the dicomdirtests DICOMDIR file. The DICOMDIR file itself
was created using the dcmtk program dcmgpdir. It complained about different
Specific Character Set in some of the files, so some with 2022 IR6 were set
to ISO_IR 100.


Patient: 77654033: Doe^Archibald
    Study 2: 20010101: XR C Spine Comp Min 4 Views
        Series 1:  CR: (1 image)
            ['./77654033/CR1/6154']
        Series 2:  CR: (1 image)
            ['./77654033/CR2/6247']
        Series 3:  CR: (1 image)
            ['./77654033/CR3/6278']
    Study 2: 19950903: CT, HEAD/BRAIN WO CONTRAST
        Series 2:  CT: (4 images)
            ['./77654033/CT2/17106',
             './77654033/CT2/17136',
             './77654033/CT2/17166',
             './77654033/CT2/17196']

Patient: 98890234: Doe^Peter
    Study 2: 20010101:
        Series 4:  CT: (2 images)
            ['./98892001/CT2N/6293',
             './98892001/CT2N/6924']
        Series 5:  CT: (5 images)
            ['./98892001/CT5N/2062',
             './98892001/CT5N/2392',
             './98892001/CT5N/2693',
             './98892001/CT5N/3023',
             './98892001/CT5N/3353']
    Study 428: 20030505: Carotids
        Series 1:  MR: (1 image)
            ['./98892003/MR1/15820']
        Series 2:  MR: (1 image)
            ['./98892003/MR2/15970']
    Study 134: 20030505: Brain
        Series 1:  MR: (1 image)
            ['./98892003/MR1/4919']
        Series 2:  MR: (3 images)
            ['./98892003/MR2/4950',
             './98892003/MR2/5011',
             './98892003/MR2/4981']
    Study 2: 20030505: Brain-MRA
        Series 1:  MR: (1 image)
            ['./98892003/MR1/5641']
        Series 2:  MR: (3 images)
            ['./98892003/MR2/6935',
             './98892003/MR2/6605',
             './98892003/MR2/6273']
        Series 700:  MR: (7 images)
            ['./98892003/MR700/4558',
             './98892003/MR700/4528',
             './98892003/MR700/4588',
             './98892003/MR700/4467',
             './98892003/MR700/4618',
             './98892003/MR700/4678',
             './98892003/MR700/4648']